10 MAINTENANCE
Good preventive maintenance and regular inspection ensure
long working life. In the table below you will find a listo f inspec-
tions/maintenance operations to be programmed and executed
periodically.
Consult the TROUBLE-SHOOTING" table whenever anoma-
lies are observed in order to find the solution to the problem and
contact DEA System directly whenever the solution required is not
provided.
Description
When the opening command is given, the gate wing
fails to move and the operator's electric motor fails to
start.
When the opening command is given, the motor starts
but the gate leaf fails to move.
The operator jerks or is noisy during movement, it
stops midway or else it does not start.
11 PRODUCT DISPOSAL
WARNING In line with EU Directive 2002/96/EC for waste electrical and electronic equipment (WEEE), this electrical product
must not be disposed of as unsorted municipal waste. Please dispose of this product by returning it to your local municipal col-
lection point for recycling.
INTERVENTION TYPE
cleaning of external surfaces
checking of screw tightening
checking of release mechanism operation
greasing of articulated joint
TROUBLE-SHOOTING
The operator is not receiving correct power supply. Check all connections, fuses, and the
power supply cable conditions and replace or repair it if necessary. If the gate does not
close check if the photocells work properly.
Make sure the unlocking system is closed.
Make sure that the electronic device for power adjustment is in good condition.
If the leaf of the gate does not move freely, release the operator and readjust the rotation
points.
The power of the gearmotor may be insufficient for the characteristics of the gate's leaf;
check the choice of model whenever required.
If the plate fastening the operator to the gate bends or is inappropriately fastened, repair it
or reinforce it.
PERIODICITY
Possible solutions
6 months
6 months
6 months
1 year
25