Terminals
WARNING OUT terminal
The VCR outputs a signal from the WARNING OUT
terminal when something wrong has happened to the
VCR during recording:
– when the recording stops due to an entangled tape
– when the APC detects an improper video signal
level at the start of recording
– when an improper video signal level is detected by
the recording checking function
WARNING OUT terminal
GND terminal
REC mode
Output
signal
Recording stops.
5 V
0 V
To reset, press one of the
tape operation buttons.
EJECT IN/OUT terminals
If you connect the EJECT IN/OUT terminals of the
VCRs, you can eject the tape inserted into all the
connected VCRs simultaneously in the following
cases:
– when you press 6 EJECT of VCR 1
– when you press the EJECT buttons on the RM-
V200 Remote Control Unit (not supplied)
– when you input a signal from an external switch
VCR 1
to EJECT OUT
VCR 2
to EJECT OUT
VCR 3
When using the RM-V200 Remote Control Unit
Connect the RM-V200 to the CONTROL S IN jack of
VCR 1, and connect the VCRs via the CONTROL S
IN and OUT jacks.
For connecting the CONTROL S IN and OUT jacks, see
page 26(US).
When using an external switch
Connect the external switch between the EJECT IN
terminal and the GND terminal of VCR 1.
to EJECT IN
to EJECT IN
23
(US)