Intended use

The electronic AC•THOR Photovoltaic-Power-Manager (in the following, AC•THOR for short) is
designed for operating resistive loads such as electric immersion heater elements, electric
boilers, electric convectors, electric heating mats or infrared panels.
The unit controls the output voltage according to external signals (temperatures, Ethernet- and
other control signals) linearly and thus the power output of the connected load.
The AC•THOR is controlled by the my-PV Power Meter or can be combined with products of
different manufacturers (the current list of manufacturers can be seen under www.my-pv.com).
The AC•THOR is designed for fixed installations indoors.
In sanitary facilities, the relevant regulations must be observed!
Any application other than those described above may cause damage.
Furthermore, this may lead to hazards such as a short circuit, fire, electric shock, etc. The safety
instructions and the information on handling in this manual and in the operation instructions
shall be followed!
The product complies with the statutory, national and European requirements. The names of
the company and products are trademarks of my-PV GmbH. All rights reserved.
You will find a comprehensive description of the unit's functions and potential settings
using the display or via web interface in the online Operating instructions.

Scope of supply

AC•THOR Electronic Photovoltaic Power Manager
Wall bracket (on the rear of the unit)
Assembly set (3 screws 4.2 x 32 mm, 3 wall-plugs 6 mm)
my-PV digital temperature sensor (cable length 5 m) with 8-pin plug
Plug, 3-pin for 16 A switch output (attached to the unit)
Operator stylus for the display with holder
Assembly Instructions
Key-fob AC•THOR

Safety instructions

The AC•THOR is designed for fixed installations indoors.
The connected units may only be pure resistive electric loads such as immersion heater
elements, boilers, convectors, heating mats or infrared panels! The units connected must
be suitable for variable supply voltages between 0-230 V AC (in no circumstances units
with electronic power supply) as this otherwise may cause damage to the AC•THOR or to
the other loads connected to it.
Only connect loads fitted with suitable mains plugs to the load socket!
In cases where the load to be connected has no mains plug, a 16 A earthed EURO mains plug
must be fitted (not supplied).
Operation of heating systems incorporating electronic thermostats is not possible!
For heating water, only heaters with an integral safety temperature limiter may be connected.
Installation must be carried out by an accredited specialist.