Errors And Faults - Trotec TTK 30 S Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 70

Errors and faults

The accurate functionality of the device was tested
during production a number of times. However, if
functionality faults do occur, then check the device
according to the following list.
The device does not start:
• Check the mains power
(230 V/1~/50 Hz).
• Check the mains plug for damages.
• Have the electrics checked by a specialist compa-
ny for cooling and air-conditioning or by
®
TROTEC
.
The device runs but forms no condensation:
• Check the condensation tank is positioned correct-
ly. Check the fill level of the condensation tank and
empty it if necessary. The condensation tank
indicator light must not light up.
• Check the float in the condensation tank for
damages. If necessary, clean the float and
condensation tank. The float must be able to move
freely.
• Check the room temperature. The working range
of the device is between 5 °C and 35 °C.
• Ensure that the relative humidity complies with the
technical data (min. 49 %).
• Check the set level of operation. The humidity in
the room must be above the selected range. If
necessary, turn the selector switch (12) clockwise
to "Hi".
• Check the air filter is not dirty. If necessary, clean
or replace the air filter
(see chapter "Maintenance").
B - 8
• From the outside, check the condenser is not dirty
(see chapter "Maintenance"). If your condenser is
dirty, have it cleaned by a specialist company for
cooling and air-conditioning or by TROTEC
The device is loud or vibrates; condensation leaks:
• Check whether the device is standing upright and
on an even surface.
The device gets very warm, is loud or is losing
performance:
• Check the air inlets and air filter are not dirty.
Remove external dirt.
• Check the inside of the device and especially the
fan, the fan housing, the evaporator and the
condenser for external dirt
(see chapter "Maintenance").
If the inside of the device is dirty, have it cleaned
by a specialist company for cooling and air-condi-
tioning or by TROTEC
The device stops while dehumidifying:
• Check whether the room temperature is above or
below the specified operating temperature
(see chapter "Technical Data").
Wet laundry does not dry:
• Point the air flow onto the washing.
• Check the room temperature. Ensure the room
temperature is sufficiently high.
Does your device still not operate correctly after
these checks?
Bring the device to a specialist company for cooling
and air-conditioning or to TROTEC
Operating manual - Dehumidifier TTK 30 S
®
®
.
®
for repairs.
.
EN

Publicidad

Tabla de contenido
loading

Tabla de contenido