Pull the nozzle holder out of the suction opening.
Pull out the spray nozzle.
Clean the spray nozzle.
Note:
Do not transpose the spray nozzles, the front nozzle has a
different bore diameter.
10.5.33 Replace the suction opening rollers (for
sweepers)
1 Running roller
2 Fastening nut
Remove the fastening nuts of the running rollers.
Replace the running rollers.
Replace the fastening nuts of the running rollers.
Adjust the running rollers in such a way that the suction
lip has a floor clearance between 0 and 1 mm all
around.
Tighten the fastening screws.
10.6 Fuses
NOTICE
Only use fuses with identical safety ratings.
Replace defective fuses.
10.6.1 Replacing the fuses in the fuse box in the
driver cabin
1 Cover
2 Knurled head screw
Unscrew the knurled screws and remove the cover.
1 2 3 4 5 6 7 8
9
Fuses driver's cab
1
Free switch location in the ceiling panel
(second location from the right)
2
Car radio connection
3
Working light
4
Switch for option (e.g. heated outside mir-
rors)
5
Wiper
6
Windscreen washer system
7
Overall lamp
8
Cabin lighting
9
Relay high beam
32
-
EN
10 A
3 A
10 A
10 A
10 A
3 A
7.5 A
3 A
69