ENGLISH
EN
MAINTENANCE
Maintenance For The Squeegee
To remove the squeegee, follow this procedure:
1. Remove the squeegee assembly by loosening the two knobs that attach
the squeegee to the machine. Pull the squeegee assembly off. See
fi gure 25.
2. Inspect the squeegee blades.
3. If the blades are worn, unclamp bands and turn the blade so that a new
edge is in the wiping position (see fi gures 25A and 25B).
4. Reinstall squeegee assembly on the machine.
Adjusting Squeegee Tilt
The tilt of the squeegee causes the rear blade to raise up in the center or
on the ends, depending on which direction the tilt is changed. Turn
the adjusting screw clockwise or counterclockwise (see fi gure 26), to
achieve uniform squeegee blade fl are.
WARNING:
Maintenance and repairs must be done by au-
thorized personnel only.
WARNING:
Electrical repairs must be done by authorized
personnel only.
Maintenance Procedures Must Be Done :
Contact a Clarke Authorized Service Center
to perform these procedures.
Every 500 hrs (heavy) 1000 hrs (normal)
1. Check the carbon brushes in the electric motors.
2. Clean the battery terminals and connectors. Make sure all of the battery
connections are tightened correctly.
3. Check all of the switches, controls, valves, hoses and gaskets.
4. Check and remove debris from the transaxle hubs.
Every 250 hrs (BOOST Only)
1. Isolators are expected to last 250-1,000 hours depending on the ap-
plication.
2. Replace lower isolators annually or after every 250 hours, whichever
comes fi rst.
-24- FORM NO. 71483A
revised 8/12
Clarke
®
Operator's Manual (EN) - FOCUS II MID-SIZE AUTOSCRUBBER
Figure 25
Figure 25A
Figure 25B
Figure 26
®