7.2.2
Setting up lighting elements
▶ If you want to set up lighting elements, proceed as illustrated here.
7.3
Checking the plumb point
1. Make a mark on the floor (a cross) in a high room (e.g. in a stairwell or hallway with a height of 5-10 m).
2. Place the tool on an even, level surface.
3. Switch the tool on.
4. Position the tool with the lower beam on the center of the cross.
5. Mark the position of the vertical beam on the ceiling. Attach a piece of paper to the ceiling before making
the mark.
6. Pivot the tool through 90°.
The lower plumb beam must remain on the center of the cross.
7. Mark the position of the vertical beam on the ceiling.
8. Repeat the procedure after pivoting the tool through 180° and 270°.
The resulting 4 marks form a circle in which the intersection of the diagonals d1 (1-3) and d2 (2-4)
marks the exact center of the plumb point.
9. Calculate accuracy as described in the section. → page 15
7.3.1
Calculation of accuracy
▶ The result (R) provided by this formula (RH = room
height) refers to the tool's accuracy "in mm at 10 m";
see formula (1). This result (R) should be within the
specification for the tool: 1.5 mm at 10 m.
8

Care and maintenance

8.1

Cleaning and drying

1. Blow dust off the glass.
2. Do not touch the glass with the fingers.
3. Use only a clean, soft cloth for cleaning. If necessary, moisten the cloth slightly with pure alcohol or a
little water.
Do not use any other liquids as these may damage the plastic components.
4. Observe the temperature limits when storing your equipment, especially in winter / summer if the
equipment is kept inside a motor vehicle (-25 °C to +60 °C).
8.2
Storage
1. Remove the tool from its case if it has become wet. The tool, its carrying case and accessories should
be cleaned and dried (at maximum 40°C / 104°F). Repack the equipment only once it is completely dry.
2. Check the accuracy of the equipment before it is used after a long period of storage or transportation.
3. Remove the batteries from the appliance before storing it for a long period. Leaking batteries may
damage the appliance.
8.3
Transport
▶ Use the Hilti packaging or packaging of equivalent quality for transporting or shipping your equipment.
Always remove the batteries/rechargeables before shipping this tool.
8.4

Hilti Calibration Service

1. We recommend having the tool checked by the Hiliti Calibration Service at regular intervals in order to
verify its reliability in accordance with standards and legal requirements. The Hilit Calibration Service is