4 Maintenance
4.1 Cleaning
Before commencing any maintenance work disconnect the electrical
power supply by pulling out the plug!
Remove any oil and dirt from the shearing plant by means of a dry
cloth. Do not use liquids!
4.2 Service
For safety reasons the portable shearing plant should be subjected
to an annual inspection. It is important that the self-tensioning belt is
checked periodically, since the functionality of the patented safety cut-
out device is dependent on this.
4.3 Lubrication
Lubricate the handpiece in accordance with the manufactures speci-
fications, since a lack of lubrication is the most common source of
faults for unsatisfactory shearing results.
4.3.1 Shearing plant
Requires no lubrication.
4.3.2 Flexible drive
prior to each period of operation
Oil the flexible drive prior to use, and, at least each time the cutters
are replaced (Diag. 4, pos. a).
Diag. 4
after 100 hours of operation
The flexible drive is fitted with sealed and permanently lubricated
ball bearings. The rotating shaft bore must, however, be greased at
regular intervals (after approximately 100 hours of operation or every
2 years). To perform this task dismantle the flexible drive in order to
remove old grease residue from the shaft bore. Then re-lubricate the
shaft bore along its whole length with fresh, high-quality mineral gre-
ase.
4.3.3 Shearing handpiece
See operating instructions for shearing handpiece.
10
ONE Shearing Plant – Instruction Manual