SYSTEM SETTINGS (settings)
To access system settings, press the MODE button repeatedly until "Menu DMX Addr" or "Menu Mode" appears in the display. Now select
the menu item "Menu Settings" using the UP and DOWN keys and press ENTER. Now select the desired sub-menu item, but this time with
the buttons UP and DOWN and confirm with ENTER (see tables, note sub-menus).
Settings
Display Rev
=
rotate display by
180°
Display
=
automatic display
shutdown
DMXFail
=
operating status
with DMX signal
fault
Dim.Curve
=
Dimmer curve
Dimmer Resp.
=
dimmer sensitivity
IR Remote
=
activate or deacti-
vate control by IR
remote control
Mode
ENTER
DMX
/
Mode
ENTER
Sound
UP/DOWN
/
Mode
ENTER
Slave
/
Mode
ENTER
Static
UP/DOWN
ENTER - UP/DOWN
Display Rev On
Display Rev Off
Display On
Display Off
Hold
Blackout
Linear
Exp
Log
S-Curve
LED
Halogen
On
Off
DMX Mode
ENTER
03CH
Mic Sens
00 -99
ENTER
Static
Static
-
Dimmer
Dimmer Fine
ENTER - UP/DOWN
Dimmer
Dimmer Fine
000 - 255
000 - 255
ENTER
ENTER
= rotate display by 180° (e.g. for overhead installation)
= normal orientation of the display
= permanently on
= automatic display shutdown after approximately 1 minute of
inactivity.
= last command is retained
= activates blackout
= light intensity increases linearly with DMX value
= light intensity can be finely adjusted at lower DMX values and
broadly adjusted at higher DMX values
= light intensity can be broadly adjusted at lower DMX values and
finely adjusted at higher DMX values
= light intensity can be finely adjusted at lower and higher DMX
values and broadly adjusted at medium DMX values
= spotlight responds abruptly to changes in DMX value
= spotlight behaves like a halogen spotlight with soft brightness
changes
= IR remote control activated
= IR remote control deactivated
Static
-
Strobe Func.
ENTER - UP/DOWN
Strobe Func.
000 - 255
ENTER