Remarks:
Input Sensitivity as follows:
When ≤ 100kHz: ≥ 300mV rms
When > 100kHz: ≥ 600mV rms
Input amplitude a: 300mV ≤ a ≤ 10V rms
G. Duty Cycle
Range
0.1%~99.9%
H. DC Current
Range
40A
400A
1000A
I. AC Current
Range
Resolution
40A
400A
1000A
Resolution
0.1%
Resolution
0.01A
0.1A
1A
Accuracy
(2.5%+8)
0.01A
(2.5%+5)
0.1A
(2.0%+2)
0.1A
Accuracy
For reference only
Accuracy
(2.0%+5)
(2.0%+3)
(1.5%+5)
Frequency Response
50Hz ~ 60Hz
Overload protection
DC1000V/AC750V
Overload protection
1000A DC/AC
Overload protection
1000A DC/AC