UK
OPERATION
CONTROL PANEL
The control panel is located below the doors on the rear of the appliance
TURN ON
1 Close the doors of the appliance
2 Connect the appliance to a mains power supply
3 Press the
button to turn the light On or Off as required
SETTING THE OPERATING TEMPERATURE
1 Press the
button The display will flash
2 Press the
or
buttons to display the required temperature
3 Press the
button to store the temperature
TABLE OF CONTROLLER PARAMETERS
The operating parameters of this appliance have been preset for optimum performance and to maximise the life of the
appliance
DISPLAY
E1
E2
E3
E4
E5
E6
F1
F2
F3
F4
SETTING THE OPERATING TEMPERATURE
1 Press and hold the
2 Press the
or
buttons tuntil the required value is displayed
3 Press the
button to store the new value and cycle to next parameter
NOTE: The controller times out after 10 seconds if no buttons are pressed
MANUAL DEFROST
Press and hold the
button for 6 seconds to begin automatic defrost The defrost light illuminates
PARAMETER
Lower set temperature
Upper set temperature
Temperature buffer
Temperature buffer time delay
Fixed parameter
Fixed parameter
Defrost period
Defrost interval
Defrost temperature
Centigrade/Fahrenheit
button for 6 seconds The „E1" parameter is displayed
Stand V11/2017 O/IH/SA V12 10/2018 TM
PRESET VALUE
0 °C
12 °C
4 °C
3 minutes
0
00
25 minutes
6 hours
20 °C
0 °C
RANGE
-20 °C to 2 °C
2 °C to 45 °C
1 °C to 10 °C
0 to 10 minutes
DO NOT CHANGE
DO NOT CHANGE
1 to 60 minutes
1 to 24 hours
0 °C to 22 °C
°C / °F
5