12. Faults
The motor fails to start
Causes
No voltage
Pump impeller is blocked - thermostat has switched off
The pump fails to draw in any water
Causes
Suction valve is not in the water
No water in the pump compartment
There is air in the suction line
Suction valve has a leak
Suction basket (suction valve) is clogged
Max. suction head exceeded
Insufficient delivery rate
Causes
Suction head is too high
Suction basket is dirty
Level of water sinks rapidly
Pump output reduced by contaminants
The thermostat switches off the pump
Causes
Motor overloaded - excessive friction
caused by foreign bodies
Caution!
Do not allow the house waterworks to run dry.
13. Ordering replacement parts
Please quote the following data on all orders for replacement parts:
Type of appliance
Art. No. of the appliance
Ident No. of the appliance
Replacement part No. of the part required
We wish to draw express attention to the fact that, in accordance with the Product Liability Law, we shall not
be liable for any damage resulting from our appliances if said damage was caused by an incorrect repair, or if
any parts were replaced by parts other than original Einhell parts or parts approved by us, or if the repair was
not performed by the ISC Customer Service.
Remedies
Check the power supply
Dismantle the pump and clean it
Remedies
Place the suction valve in the water
Fill water in the suction connection
Check the suction line for leaks
Clean the suction valve
Clean the suction basket
Check the suction head
Remedies
Check the suction head
Clean the suction basket
Place the suction valve deeper
Clean the pump and replace worn parts
Remedies
Dismantle the pump and clean
Prevent foreign bodies from being drawn in
(filter)
GB
9