Control Board (With GFI Filter Coil)
Follow the steps below:
1. Plug cord in and turn switch ON. Connect wires
to control board and ON/OFF switch. Meter on AC
Volts.
110-120 AC
V
-
Black to board
Black from power cord
ti13138a
2. Plug cord in and turn switch ON. Connect wires
to control board and ON/OFF switch. Meter on
AC Volts.
110-120 AC
V
-
Black to board
Black from power cord
ti13139a
311287E
White from power cord
White from power cord
3. Check motor thermal switch. Unplug thermal wires
(see table below for proper reading).
NOTE: Motor should be cooled down.
-
Resistance Table:
Ironman 300E
695
795
1095
1595
4. Plug cord in and turn switch ON. Disconnect
potentiometer and carefully create a short between
potentiometer terminals.
ti13141a
Refer to Wiring Diagram, page 87, for more details.
Cleanup / Nettoyage / Limpieza
ti13140a
8.2k ohms
0 ohms
2k ohms
3.9k ohms
6.2k ohms
Control Board