Beurer LB 55 Instrucciones De Uso página 19

Humidificador de aire
Ocultar thumbs Ver también para LB 55:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 32
Disassemble the appliance
• Remove the cover [2] from the air humidifier.
• Pull the water tank [8] out of the air humidifier using the handles [7]. Unscrew the tank catch [9] from the
tank [8].
• Pull up the steam tower [3] out of the air humidifier. Remove the steam nozzle [1] from the steam tower [3].
• Remove the pad [4] from the hotwater chamber.
Cleaning the appliance
Clean the inside and outside of the appliance
WARNING
• Electrical parts must never come into contact with water.
• Never hold the appliance under running water or immerse in water.
• If there is any water left in the appliance, pour it away. To do this, hold the appliance with both hands
and tip the water out from the side of the base unit.
• Rinse out the inside of the appliance thoroughly with clean water.
• Wipe the outside of the air humidifier casing [6] with a damp cloth and mild cleaning agent.
Clean individual parts
• Wash the pad [4] with clean water. You can remove stubborn limescale by first putting the pad [4] in a weak
vinegar solution. If the pad [4] is hard and rigid, it must be replaced (see next section 3 'Changing the pad').
• Clean the following individual parts of the appliance thoroughly with washing-up liquid and warm water.
Any residue from cleaning agents should be thoroughly removed.
• Tank [8] and tank catch [9]. When cleaning the tank catch [9], do not damage the valve.
• Steam tower [3] and steam nozzle [1].
• Cover [2].
Changing the pad
Note
• Pads are obtainable from the service address or from the authorised dealer.
• Remove the worn pad [4] from the hotwater chamber. Dispose of the pad in the household refuse.
• If there is any water left in the appliance, pour it out.
• Use a new pad [4].
• Wash out the new pad [4] with clean water and put in the hotwater chamber.
Descaling the appliance
Descale the air humidifier
Note
• Never try to remove any limescale deposit with pointed or sharp objects. This might damage the air
humidifier or cause it to leak.
• You should also note the manufacturer's advice for the descaling agent which you are using.
• Use a standard commercial descaling agent.
• Fill the hotwater chamber up to the brim with descaling solution.
• Leave the descaling solution to work until the limescale has dissolved.
• Pour away the descaling solution. Tip the appliance sideways to remove the descaling solution.
• Rinse out the appliance thoroughly with clean water.
19