1.
Once the gas conversion operations have been completed, check the dismantled parts for leaks using soapy water
or foam products. DO NOT SEARCH FOR LEAKS WITH NAKED LIGHTS.
Before delivering the appliance to the user:
•
check that it operates correctly,
•
instruct the user on how to use it.
2.
The appliance must be used only for the purpose for which it was designed. Any other use is improper. During
operation, supervise the appliance.
2.1
Commissioning
Before starting up the appliance for the first time, unpack it.
•
Check that no obstacle inside the appliance obstructs the air flow required for combustion and check that
the premises are sufficiently ventilated.
•
Check the efficiency of the devices for evacuating cooking fumes (extraction hood, discharge collector,
etc).
•
Use gloves to work on the appliance.
2.2
Setting
INSTALLATION
OPERATING INSTRUCTIONS
Manuale d'installazione e d'uso
MINIMUM ADJUSTMENT:
Remove the knob and the front cover.
To adjust to minimum, adjust the screw (Ref. 1): loosen
to increase the flame and tighten to decrease the flame.
For liquid petroleum gas, turn the screw to minimum.
When the flame is in the minimum position, check that it
is stable along the whole burner surface and check that
when the flame is increased from minimum to maximum
the flame does not go out and that the nozzle does not
catch fire.
The control knobs (Fig.5) of the burner taps have 3
positions:
shut
maximum flame
minimum flame
EN
13