10
Troubleshooting
If the trouble you are experiencing is not listed in this table or you are unable to remedy the problem by
yourself, please contact Hilti Service.
10.1
Troubleshooting
Trouble or fault
Product does not start.
Product does not develop full
power.
11
Disposal
Most of the materials from which Hilti tools and appliances are manufactured can be recycled. The
materials must be correctly separated before they can be recycled. In many countries, your old tools,
machines or appliances can be returned to Hilti for recycling. Ask Hilti Service or your Hilti representative
for further information.
▶ Do not dispose of power tools, electronic equipment or batteries as household waste!
12
RoHS (Restriction of Hazardous Substances)
Click on the links to go to the table of hazardous substances: qr.hilti.com/r2328153.
There is a link to the RoHS table, in the form of a QR code, at the end of this document.
13
Manufacturer's warranty
▶ Please contact your local Hilti representative if you have questions about the warranty conditions.
Mode d'emploi original
1
Indications relatives à la documentation
1.1
À propos de cette documentation
•
Lire intégralement la présente documentation avant la mise en service. C'est la condition préalablement
requise pour assurer la sécurité du travail et un maniement sans perturbations.
•
Bien respecter les consignes de sécurité et les avertissements de la présente documentation ainsi que
celles figurant sur le produit.
•
Toujours conserver le mode d'emploi à proximité du produit et uniquement le transmettre à des tiers
avec ce mode d'emploi.
24
Français
Possible cause
Interruption in the electric supply.
The supply cord or plug is defec-
tive.
The carbon brushes are worn.
The restart interlock is activated af-
ter an interruption in the electricity
supply.
The extension cord conductor
cross section (gauge) is inade-
quate.
Action to be taken
▶ Plug in another electric tool or
appliance and check whether it
works.
▶ Have the supply cord and plug
checked by a trained electrical
specialist and replaced if
necessary.
▶ Have the power tool checked by
a trained electrical specialist and
the carbon brushes replaced if
necessary.
▶ Switch the product off and then
on again.
▶ Use an extension cord with
an adequate conductor cross
section.
2075442
*2075442*