FEATURES

CONTROL PANEL FEATURES

1
12
2
7
6
Engine Control Switch/Battery Disconnect:
1
• START - When the switch is momentarily
depressed and held in the START position,
the electric start motor engages and starts the
engine. Once the engine starts, release the
switch. (The switch will automatically go to the
RUN position).
• RUN - Once started, the switch will remain in the
RUN position
• STOP - To stop the engine, move the switch to
the STOP position. The battery will disconnect in
the STOP position to save battery life.
Battery Charging Port: Charge the battery when
2
the unit is off with trickle charger.
3
USB Duplex: Two 5V DC USB ports.
Data Center: This VFT Meter is a four function unit.
4
Function 1 will be the first thing you see. This is
your Frequency. Press the button once and you will
go to the function 2, which is not being used. Press
the button once more and you will see function 3
for your time/Hours and by pressing one final time
you will see function 4, which is the voltage.
The frequency and voltage can vary +/- 5% and
still be within tolerance.
F - 6 0
0 0 0 0
0 0 0 7
U 2 5 0
4
3
8
9
Frequency
Inoperative
Lifetime run hours
Voltage
1
5
11
5
GFCI Circuit Breaker: The main circuit breaker
controls total output of all outlets to protect the
generator. This GFCI breaker allows for full panel
GFCI and is OSHA compliant.
6
120-Volt, 20-Amp Duplex Outlets
(NEMA 5-20R): Each outlet is capable of carrying
a maximum of 20 amps on a single receptacle or
a combination of both receptacles.
20-Amp Circuit Breakers: Each circuit breaker
7
limits the current that can be delivered through
the 120-volt duplex outlets to 20amps.
120-Volt, 30-Amp Twist Lock Outlet
8
(NEMA L5-30R): Outlet can supply
120V up to 30 amps.
120/240-Volt, 30-Amp Twist Lock Outlet
9
(NEMA L14-30R): Outlet can supply either
120V or 240V up to 30 amps.
120/240-Volt, 50-Amp Outlet (NEMA 14-50R):
10
Outlet can supply either 120V or 240V up
to 50 amps.
Ground Terminal: The ground terminal is used to
11
ground the generator.
Remote Start Program Button: Use this button
12
along with the key fob to program the generator
to be started remotely. Button located on side of
control panel on WPro12000.
4
3
2
7
8
9
6
Westinghouse Outdoor Power Equipment | 11