EXHAUST FILTER REPLACEMENT
1. Turn off and unplug vacuum cleaner.
2. Carefully turn machine on its side and remove exhaust cover from
bottom of machine.
3. Remove the two nuts holding filter onto machine.
4. Replace filter in proper position and tighten nuts.
5. Reinstall exhaust cover.
*Replace exhaust filter every 6 months.
BELT ADJUSTMENT AND REPLACEMENT
1. Turn off and unplug vacuum cleaner.
2. Remove belt cover on left side of machine.
3. Loosen the motor belt adjusting screws on motor bracket.
4. Remove belt.
5. Install new belt and reposition motor to eliminate excess slack.
6. Once proper tension is set, tighten motor adjusting screws.
7. Replace belt cover on side of machine.
VACUUM MOTOR FILTERS
VACUUM MOTOR FILTERS
1. Turn off and unplug vacuum cleaner.
2. Position the handle in normal operating position.
3. Open Wide Area Vacuum lid and rest it on the handle.
4. Remove clamp with a screwdriver to gain access to filter
5. Remove plastic cap covering the motor
6. Remove plastic retainer in cap
7. Replace filters in their original positions.
8. Reinstall plastic retainer in cap
9. Reinstall cap onto motors
10. Reinstall clamp.
*Clean the filter every six months and replace as needed.
MACHINE SPECIFICATIONS
Model
Voltage / Frequency
Vacuum motor rating
Brush Motor rating
Total power consumption`
Bag capacity – dry
Airflow
Vacuum – water lift at sealed orifice
Filtration - HEPA
Vibration at controls
Brush width
Cable length
Weight (including cord)
Noise level
Construction class
Protection
Machine dimensions
ELECTRICAL DIAGRAM
7
V-WA-30
120 V / 60 Hz
1512W / 12.6 A
1/4 hp / 2 A
14 A
45.5 qt / 43 L
226 cfm / 384 m 3 /h
71 in / 1804 mm
99.97% @0.3 micron
< 2.5 m/s 2
30 in / 762 mm
75 ft / 23 m
95 lb / 43.09 kg
69.9 dB(A)
I
IP20
Folded: 33" X 31" X 19"
Operating Position:
33" X 31" X 39"