• BASE INTERNAL FILTER: Located in the tray, it is responsible for
filtering the water excess that decants from the straw filter. The water
is recycled and sent back to the water tank totally clean. That´s why it is
essential to keep it always clean.
Procedure: At most, every 2 (two) months, pass an air blast through the
tissue, since if there is too much dirt in the filter, it will stop the passage
of the water, leading to a possible leakage.

WATER PUMP:

• INJECTION: Located in the water tank, it sends the water to the
evaporative straw filter.
• RETURNING: Located in the tray, it sends the excess of water back to
the water tank.
Note: Take out the pumps every 2 (two) months and clean them
with an air blast. We suggest to change them every 6 (six) months.
• BASE PRE-FILTER: Located at the tray is responsible for 2nd filtering
process, avoiding the entry of dirt into the pump. It avoids clogging and
the breakdown of the pump.
Procedure: At least every 2 (two) months apply some air blast and / or
wash it. As the time passes it is normal dirt accumulate and it lowers the
perfomance of equipment or may even cause water leakage.
Note: In case of most severe application of the roof air cooler, with
high accumulation of dirt, cleaning should be performed more
often.
A periodical maintenance is essential for the
best performance of your Resfri Ar roof air cooler.