4 3-WIRE POWER CORD
INSTALLATION
WARNING:
of the power cord must be connected to the
neutral terminal located in the center of the
terminal block. The power leads must be
connected to the left and the right terminals of
the terminal block.
A
Remove the 3 lower terminal screws from the
terminal block. Insert the 3 power cord
terminal rings into each one of the terminals of
the terminal block. Be certain that the center
wire (white/neutral) is connected to the center
of the terminal block. Tighten nuts securely
into the terminal block.
DO NOT remove the ground strap
connection.
Ground
plate
Power
cord
B
Skip to Step 8 and proceed with the
installation.
Installation Instructions
The neutral or ground wire
Terminal block
(appearance
may vary)
Neutral
terminal
Ground
strap
5 4-WIRE POWER CORD
INSTALLATION
WARNING:
supply circuit must be connected to the neutral
terminal located in the center of the terminal
block. The power leads must be connected to the
left and the right terminals of the terminal block.
The 4th grounding lead must be connected to the
frame of the range with the ground plate and the
ground screw.
A
Remove the 3 lower terminal nuts from the
terminal block. Remove the ground screw and
ground plate and retain them.
B
Cut and discard the ground strap. DO NOT
DISCARD ANY SCREWS.
C
Insert the one ground screw into the power cord
ground wire terminal ring, through the ground
plate and into the frame of the range.
D
Insert the 3 terminal screws (removed earlier)
through each power cord terminal ring and into the
lower terminals of the terminal block. Be certain that
the center wire (white/neutral) is connected to the
center lower position of the terminal block. Tighten
screws securely into the terminal block.
Before
Terminal
block
Ground strap
After
Terminal
block
Ground
screw
E
Skip to Step 8 and proceed with the installation.
33
The neutral wire of the
Ground strap
or
GROUND
Neutral
terminal
Neutral terminal
Ground
plate
(grounding
to range)