Descargar Imprimir esta página

KEY 900SEZ Manual De Instrucciones página 18

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 39
!/!'-*$'+/ ',%%!'-$,%
Thanks to visual diagnosis by means of LED' s, you can check for correct wiring safely and quickly. For
connection, proceed as follows:
1.
Control for step/step open/close
and COM-
2.
F.T. safety Photocell
operation; it is connected between terminals F.T. and COM. This device is active only in closing and
reverses the direction of movement if the ray is interrupted.
3.
Safety STP Stop
is connected between terminals STP and COM. This contact can be interrupted at any time,
completely shutting down the automation and disabling automatic closure if it has been enabled
4.
Power supply –COM and +24
&$8; = $-'0 7)%'-$,%
DIP N.
FUNCTION
1
Shared operation
2
Operation of P/P command
3
Automatic closing
4
Chain return
N.b.:each function variation is confirmed upon completion of closure
PROGRAMMING OF WORKING TIMES AND PAUSE IN SELF-LEARNING
1.
Place the automated door at about half its travel
2.
Hold down the PROG key for 2 sec. The flasher and the courtesy light will come on steady to inform
you that you have entered the programming procedure
3.
Press the P/P button. The door will close all the way down. After 2 seconds, it will change direction
and move to the fully open position. Or you can press the P/P button to stop the door at the desired
maximum opening position. The entire procedure of acquisition of stops is carried out in slow motion.
4.
After locating the opening stop position, the countdown for automatic closing begins. When the
desired time has elapsed, press the P/P button or the remote control button
5.
The automation will begin the closing manoeuvre until the door is fully closed.
6.
The control unit will automatically exit the programming procedure, and the courtesy light and the
flasher will go off
Operation of the electronic clutch
This device is extremely important for reasons of safety. Its calibration remains unchanged over time and is
not subject to wear as are mechanical clutches.
A.
If it intervenes two consecutive times, it will be placed automatically in the STOP position. This will
disable automatic closing if it has been activated. If it intervenes twice consecutively, it means that
there is a permanent obstacle and any other movement could be dangerous. The user must now give
the open or close command.
B.
Calibration is self-learned. The value can be increased or decreased with the trimmer TR1. Turn it
CLOCKWISE to increase motor force. Turn it COUNTER-CLOCKWISE to decrease motor force.
Contact N.O. (normally open) connected between terminals P/P
Contact N.C. (normally closed). The LED must be ON during normal
Contact N.C. (normally closed). The LED must be ON during normal operation; it
Accessory power supply terminals 24V DC I Max. 250 mA.
OFF
Step-step as per selection
DSW2
Open / Close
Not inserted
Inserted
>:
ON
During opening, will not
accept inversion or stop
commands
Open / Stop / Close
Inserted
Not inserted

Publicidad

loading