The display will then show:
F. MAINTENANCE ALARM
When the display shows:
It means that the number of cycles set in the TECHNICAL MENU has been exceeded (doses carried out in all the
machine groups).
To eliminate this alarm, set the main switch to position 0. Press the dose buttons "1 coff ee and 1 espresso" from
GROUP 1 (on the left) simultaneously. Keep them pressed while we switch on the machine by setting the main
switch to position 1.
The display will then show:
G. BOILER WATER MINIMUM LEVEL WARNING
When the machine is switched on (position 1 on the main switch) the boiler begins fi lling with water.
-
IN THE CASE OF MACHINE START-UP: When the minimum level sensor does not detect the presence
of water for longer than 6 seconds, it will disconnect the heating element and the machine will not
heat; at the same time, the display will show the alarm signal:
-
IF THE MACHINE IS BEING WORKED WITH and the minimum level sensor does not detect the
presence of water for longer than 3 seconds, it will disconnect the heating element and the machine
will not heat.
To ELIMINATE this alarm the boiler water must be fi lled; the minimum level sensor, on detecting water for more
than 3 secons, will clnnect the element and the machine will once more begin to heat.