Before taking into operation for the first time, the installation has to be approved by an expert!
5.2 Analog input
Connect your light controller with the Analog Input socket.
The occupation of the 8-pin DIN-socket is as follows:
1. Channel 1
2. Channel 2
3. Channel 3
5.3 Connection with the mains
Connect the device to the mains with the power-plug.
The occupation of the connection-cables is as follows:
Cable
Pin
Brown
Live
Blue
Neutral
Yellow/Green
Earth
The earth has to be connected!
5.4 Outputs
Output is via 4 safety sockets on the rearpanel.
Connect your loads via the output-sockets. The maximum load per channel is 1,150 W (resistive). Please
note that the maximum current of 16 A must never be exceeded.
5.5 DMX-512 control
The wires must not come into contact with each other, otherwise
Only use a stereo shielded cable and 3-pin XLR-plugs and connectors in order to connect the controller with
the device or one device with another.
Occupation of the XLR-connection:
DANGER TO LIFE!
4. Channel 4
5. Not connected
6. Not connected
International
L
N
the devices will not work at all, or will not work properly.
7. Ground
8. 15 V DC (Output)
15/31
70064222X87NXS_V_1_0.DOC