Troubleshooting - Briggs & Stratton 01917 Manual Del Usuario

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Briggs & Stratton P ower P roducts Home Generator
Owners
Manual
WERPRODUCTS
TROUBLESHOOTING
Problem
Engine is running,
but no AC
output
is available.
Engine runs good at no-load but
"bogs down" when loads are
connected.
Engine will not start; or starts and
runs rough.
Engine shuts down during
operation.
Loss of power
on essential
circuits.
Cause
I.
Circuit breaker open or defective.
2.
Fault in generator.
3.
Poor wiring connections
or
defective transfer switch.
I.
Short circuit in a connected load.
2.
Generator
is overloaded.
3.
Shorted generator
circuit.
4.
Fuel Pressure is incorrect.
5.
Natural gas fuel mixture
is
incorrect.
I.
15Amp fuse missing or blown.
2.
Out of fuel.
3.
Failed battery.
I.
Out of fuel.
2.
Fault indicator blinking.
I.
Generator
circuit breaker is open.
2.
Transfer switch problems.
Correction
I.
Reset or replace circuit breaker.
2.
Contact
local service facility.
3.
Check and repair.
I.
Disconnect
shorted electrical
load.
2.
See "Essential Circuits".
3.
Contact
local service facility.
4.
See "The Gaseous Fuel System" in
the Installation
Manual.
5.
See "The Gaseous Fuel System" in
the Installation
Manual.
I.
Install (new) 15Amp fuse. See
"KnowYour
System Control
Panel".
2.
Open fuel valve(s); check propane
tank.
3.
Replace battery.
I.
Check fuel valves, fill propane tank.
2.
Count blinks and refer to "Fault
Detection
System".
I.
Reset circuit breaker.
2.
See the transfer
switch manual.
17

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

0191801813019280181401929

Tabla de contenido