For Your Safety
Strictly follow the instructions for use
Any use of the full face mask requires full understanding and strict
observation of these instructions.
The mask may only be used for the purposes specified here.
Maintenance
The full face mask must be subjected to regular inspections and
maintenance by specialists.
Only have repairs carried out by specialists.
We recommend taking out a service contract with Dräger and having
all repairs carried out by Dräger.
Only original Dräger parts may be used for maintenance.
Note the instructions in the section entitled "Maintenance intervals".
Accessories
Only use the accessories listed in the ordering list.
Use in potentially explosive atmospheres
Full face masks that are used in potentially explosive atmospheres
and have been tested and approved to national, European or
international explosion protection standards may only be used under
the conditions specified in the approval and with regard to the relevant
statutory regulations.
No modifications may be made to the equipment.
The use of defective or incomplete parts is not permissible. The
corresponding regulations must be observed when carrying out
repairs to these components or apparatus.
Description
What's What
6
5
4
3
2
1
9
12
11
10
1
Button
2
Control valve
3
Inner mask
4
Visor
5
Visor frame
6
Front head strap
Description/Purpose
The full face mask protects the face and eyes from hostile media.
Wearers of spectacles can use mask spectacles. Usable over a
temperature range of -30 °C to +60 °C.
The full face mask has a plug-in connector. It may only be used with
approved positive pressure self-contained breathing apparatus or
positive pressure hose breathing respirator.
7
8
7
Harness
8
Face seal
9
Mask body
10 Clamping ring
11 Exhalation valve cover
12 Equipment connector
9