POS. DESCRIPTION
1
Red plastic washer
2
Yellow plastic washer
3
Blue plastic washer
4
Relief/non return valve
5
Element gasket
6A
Electric element
800W 220V
6B
Electric element
800W 110V
6C
Electric element
1200W 220V
6D
Electric element
1200W 110V
7
Bi-Thermostat
8
Boiler resistor cover
9
Nut M4 stainless steel
10A
Tank mounting
22 Lt
10B
Tank mounting
20-30-40-60 Lt
11
Metal bracket
12
Screw M8 x 20 stainless steel
13
Screw M8 x 40 stainless steel
14
Washer Ø8
15
Nut M8 stainless steel
BOILER TERMOINOX 20/60 - REV002A
CODE
PVRPC300R000
PVRPM300G000
PVRPF300B000
MNVALS120000
• shut down power supply.
PGR031430000
• Remove the protection cover (8) in order to reach
EVR08220NSG0
the thermostat (7).
• Push the reset button on the double thermostat
EVR08110NSG0
(fig. 3).
• Replace on the protection cover (8).
EVR12220NSG0
• Switch on power supply.
EVR12110NSG0
EVT101100000
PCCBRNP00000
MBD04MXEN000
SLMMFS67TRX0
MAINTENANCE
SLMMFS89TSX0
We recommend checking the magnesium anode (A)
SLMMSTSP25P0
every 12 months.
MBV0820MXE00
Replace the anode if its size has been reduced signifi-
MBV0840MXE00
cantly.
MBV08X000000
This simple and preventive maintenance will ensure a
MBD08MXEN000
long life of the equipment.
F
The overpressure release device must be activated
regularly to remove calcium deposits and to ensure that
it is not blocked.
Periodically check the joints of the water pipe installation;
check the tightness of the securing screws and replace
them in case they are worn or corroded.
Also periodically check the electrical system working
order.
MAINTENANCE
WARNING: Sigmar Marine nautic water heaters
are provided with a double thermostat with
manual reset that shuts down power supply in
case of an excessive water temperature.
If it happens, follow the instructions below:
WARNING: if the high temperature safety system
switches on repeatedly, call Sigmar Marine service
center.
During wintertime, when the water heater is not
in use it should be drained using the lever of the
valve (4). This is to avoid serious damage caused
by freezing.
GB