2) the Stapler is always held firmly against
the workpiece.
If staples are driven too deep or shallow into
the workpiece, adjust the stapling in the
following order.
1 DISCONNECT
STAPLER.
Adjuster
2 If staples are driven too deep, turn the
adjuster to the shallow side.
If staples are driven too shallow, turn the
adjuster to the deep side.
2
Turn adjuster
Too deep
2
Turn adjuster
Too shallow
3 Stop turning the adjuster when a suitable
position is reached for a stapling test.
4 Connect the air hose.
ALWAYS WEAR SAFETY GLASSES.
Perform a stapling test.
5 DISCONNECT
STAPLER.
6 Choose a suitable position for the
adjuster.
AIR
HOSE
FROM
15
Disconnect
air hose
Flush
Flush
AIR
HOSE
FROM
— 17 —