Technical Characteristics; Svrs Notes (Only Applicable To Model Svrs) - DAB E.SWIM 150 Instrucciones De Instalación Y Manual De Mantenimiento

Ocultar thumbs Ver también para E.SWIM 150:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 152
1- User panel cover
2- User panel
3- QR code
4- Quick guide
5- Terminal board cover
6- External connector
7- Power cable inlet

1.2 Technical characteristics

The technical characteristics are summed up in the table below.
Topic
ELECTRIC POWER
SUPPLY
CONSTRUCTION
CHARACTERISTICS
HYDRAULIC
PERFORMANCE
WORKING
CONDITIONS

1.3 SVRS Notes (Only applicable to model SVRS)

The Safety Vacuum Release System (SVRS) model is designed to provide an additional layer of protection against body
suction entrapment. It complies with ASME/ANSI A112.19.17 -2010 SVRS standard.
1. SVRS devices shall only be installed in conjunction with an ASME A112.19.8 suction fitting, or a 12 in. x 12 in. (305
mm x 305 mm) drain grate or larger, or an approved channel drain system at each suction outlet or drain outlet.
2. Check valves and hydrostatic valves shall not be used in suction systems protected by SVRS devices.
Parameter
Voltage
Frequency
Maximum current
Maximum power
550 x 300 x 316 mm / 22.6 x 12.2
Overall dimensions
Empty weight
(excluding
packaging)
Protection class
Motor insulation
class
Maximum head
Maximum flow rate
Maximum working
pressure
Max liquid
temperature
Max ambient
temperature
Table 1 – Technical Characteristics
ENGLISH
Figure 2
E-SWIM 150 / E.PRO 150
220-240 V +/- 10%
50/60 Hz
5.6 SFA
1250 W
x 12.4 in
18 kg / 39 lb
IP55
F
16 m / 52 ft
32 m3/h / 141 gpm
2,5 bar
40°C / 104°F
50°C / 122°F
43
E-SWIM 300 / E.PRO 300
220-240 V +/- 10%
50/60 Hz
10 SFA
2250 W
574 x 304 x 354 mm / 22,6 x 12 x
13,9 in
21,3 kg / 47 lb
IP55
F
26 m / 85,3
42,6 m3/h / 188 gpm
2,8 bar
40°C / 104°F
50°C / 122°F

Publicidad

Tabla de contenido

Solución de problemas

loading

Tabla de contenido