6.1 Error diagnosis (MOD.B)
ERROR
DESCRIPTION
1
OPEN DOOR
2
TANK FILL
3
TANK DRAINAGE
4
BOILER HEATING
5
TANK HEATING
6
BOILER FILL
6.2 Errors shown in display (MOD. C)
ERROR
DESCRIPTION
E1
Faulty boiler probe.
E2
Faulty tank probe.
E3
Tank overheating.
E4
Boiler overheating.
E5
Boiler heating faulty.
E6
Tank heating failure.
E7
The boiler does not fill.
E8
The tank does not fill.
E9
Does not drain.
48
CONSEQUENCE
The ON/OFF LED lights up for 0.5 seconds and then remains unlit for 2 seconds
before lighting up again. This continues as long as the door is open and the
selected cycle is unfinished.
The ON/OFF LED light up twice for 0.5 seconds each time and then remains unlit
for 2 seconds, then lighting up again twice. This continues while the water in the
tank does not reach the correct level in the specified time.
The ON/OFF LED lights up three times for 0.5 seconds each time and then
remains unlit for 2 seconds, then lighting up again three times. This continues
while the drainage pump does not drain the water in the tank to the correct level in
the specified time.
The ON/OFF LED lights up four times for 0.5 seconds each time and then remains
unlit for 2 seconds, then lighting up again four times. This continues while the
water in the boiler does not reach the correct temperature in the specified time.
The ON/OFF LED lights up five times for 0.5 seconds each time and then remains
unlit for 2 seconds, then lighting up again five times. This continues while the water
in the tank does not reach the correct temperature in the specified time.
Le voyant ON/OFF s'allume six fois pendant 0,5 secondes à chaque fois et reste
éteint pendant 2 secondes avant de se rallumer six fois, et ainsi de suite tant que
la chaudière n'a pas atteint le niveau correct dans le temps imparti.
DETECTION MODE
TC out of range [-5..200]
TT out of range [-5..200]
TT > 90 ⁰C
TC > 105 ⁰C
If TC<70 ⁰C, and CC is on, if
TC does not change by 3 ⁰C or
more within 5 minutes .
60 min without reaching
programmed tank temperature.
The VC is observed to have
been running for 5 minutes or
more and the PC=PC-ALTO
has not been reached.
Since the start-up of the
machine, PT=PT1 has not been
reached in a period of 30 or
more minutes.
The BD is observed to have
been running for 1 or more
minutes and the level of the tub
does not go down5mm, (PT
does not change).
CONSEQUENCE
MESSAGE: "E1-TC" and an acoustic
signal for 30 seconds every 3 minutes,
for 15 minutes. Machine completely
disabled.
MESSAGE: "E2-TT" and an acoustic
signal for 30 seconds every 3 minutes,
for 15 minutes. Machine completely
disabled.
MESSAGE: "E3-TANK" and an acoustic
signal for 30 seconds every 3 minutes,
for 15 minutes. Machine completely
disabled.
MESSAGE: "E4-BOILER" and an
acoustic signal for 30 seconds every 3
minutes, for 15 minutes. Machine
completely disabled.
MESSAGE: "E5-BOILER HEATING".
The machine is not disabled. The error
is displayed and an acoustic signal is
emitted for 30 seconds every 3
minutes, for 15 minutes.
MESSAGE: "E6-TANK HEATING". The
machine is not disabled. The error is
displayed and an acoustic signal is
emitted for 30 seconds every 3
minutes, for 15 minutes.
MESSAGE: "E7-NEEDS WATER". The
machine is not disabled. The error is
displayed and an acoustic signal is
emitted for 30 seconds every 3
minutes, for 15 minutes. Machine
completely disabled.
MESSAGE: "E8-TANK EMPTY" and an
acoustic signal for 30 seconds every 3
minutes, for 15 minutes. Machine
completely disabled.
MESSAGE: "E9-DOES NOT DRAIN"
and an acoustic signal for 30 seconds
every 3 minutes, for 15 minutes.