Technical Data; Emptying And Service - Gloria 90 Instrucciones De Uso

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 11
● When handling pesticides and other chem-
icals, remove protective clothing and wash
hands and face carefully (rinse mouth out)
before eating, drinking or smoking.
● Do not try to clear blocked nozzles by
blowing into them with your
● Caution!
Please note that under product liability law
we are not liable for damage resulting
from the use of our product if such dam-
age was caused by improper repair or if
original replacement parts are not used to
replace defective or worn out parts and
the repair was not carried out by our Cus-
tomer Service or by an authorised service
technician. This also applies to acces-
sories.
● The service life of the unit must be deter-
mined by the operator based on a risk as-
sessment, taking into account the operat-
ing conditions. Due to possible material
fatigue, we recommend that a service life
of 10 years is not exceeded.

Technical Data

Max. filling capacity:
Max. working pressure:
Max. working temperature: + 40 °C
Max. Output:
Spraying angle of nozzle: max. 60 °
Accessories: tank, valve block and pump
tubing out of plastic; safety
valve; nozzle, valve bolt and
pump rod out of plastic, Viton
seals.
mouth.
1.25 l
3 bar
260 - 940 ml/min
Operation
● Using the valve handle, unscrew the valve
by turning counter-clockwise.
● Fill with a maximum of 1.25 litre of liquid,
taking into account the safety instructions.
● Insert valve and screw tight.
● Operate pump until a working pressure of
3 bars is reached.
● The spraying process is started by the
valve lever on the valve body being de-
pressed. Immediate interruption is
achieved by letting the lever go of.

Emptying and Service

● Operate the pressure relief valve until
the unit is no longer under pressure.
● The valve handle will be carefully, at first
only a few turns by lefthand rotation
screwed off, so that the compressed air
being still in the tank can deflate. Only
then unscrew the valve handle com-
pletely.
● After use clear the sprayer carefully and
dry it in open state.
● The working life will be extended when
greasing the washers and collars some-
times. Only use resin- and acid-free
grease.
● For easy cleaning and safe neutral-
ization of remaining liquid is recom-
mended to use Brill GLORIA special
powder, art.-no. 263.0000.
5

Publicidad

Tabla de contenido
loading

Tabla de contenido