Phonic PAA3 Manual Del Usuario página 11

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

On the main RTA display, hold the ENTER button for
3.
approximately 2 seconds to activate the SPL screen.
Press the ENTER button once to exit.
NB. You can easily refresh the Max SPL value by holding
both the ← left and → right keys simultaneously for at
least one second.
RT60 (Reverb Time Analyzing)
The RT60 function of the PAA3 is easy enough to
understand: it is basically the time it takes for a signal to
drop 60 dB. Getting the average of many different RT60
calculations from around a room allows users to get an idea
as to how much absorption or reflection of audio the room
provides. Depending on your needs, you may wish to have
a high or low RT60 measurement. For example, for public
speaking, an RT60 measurement of less than 1 second
is preferable, as to have a clear, concise voice conveyed
to the audience. With choirs or instrumental music, an
RT60 measurement of greater than 1.5 seconds may be
appropriate. It all depends on your needs.
Measuring Reverb Time:
Press enter to open the main menu and select "RT60."
1.
Simply click "RUN" to get your RT60 reading.
2.
The PAA3 will wait for a signal greater than 30 dB
3.
over the background noise level (detected prior to the
measurement). A little helpful hint: the louder the test
signal, the greater accuracy of your RT60 calculation.
Play pink noise through your audio system. Slowly
4.
move the master fader up, to a point where the audio
level received by the PAA3 is greater than 30 dB.
Quickly mute the system to get your RT60 reading
as accurate as possible.
After the measurement is taken, the RT60
5.
measurement will appear onscreen.
PAA3
7

Publicidad

Capítulos

Tabla de contenido
loading

Tabla de contenido