EN
Problem
Atomisation too
coarse
Spray jet pulsates
Coating material
causes "paint tears"
Too much fog of
coating material
(Overspray)
Paint in the
ventilating hose
Poor covering
capacity on the wall
19. Technical Data
Max. viscosity
Power source
Power consumption
Atomizing output
Max. flow rate
Double insulation
Sound pressure level*
12
Cause
•
Viscosity of coating material too
high
•
Material volume too large
Material volume adjusting screw
turned too far to the right (+)
•
Nozzle contaminated
•
Air filter heavily soiled
•
Too little pressure build-up in
container
•
Coating material in container
running out
•
Air filter heavily soiled
•
Nozzle seal is missing or worn
•
Too much coating material
applied.
•
Distance to the object too large
•
Too much coating material
applied
•
Diaphragm soiled
•
Diaphragm defective
•
Spray material is too cold
•
Highly absorbent surface or paint
with poor covering capacity
•
Distance too large
Technical Data
2700 mPas
230 V, ~ 50 Hz
320 W
80 W
230 ml/min
76 dB (A); Uncertainty K = 3 dB
HV2501EU
Remedy
➞ Thin
➞ Turn material volume
adjusting screw to the
left (-)
➞ Clean
➞ Change
➞ Tighten container
➞ Refill
➞ Change
➞ Insert an intact nozzle
seal
➞ Turn material volume
adjusting screw to the
left (-)
➞ Reduce distance
➞ Turn material volume
adjusting screw to the
left (-)
➞ Clean the diaphragm
➞ Replace the diaphragm
➞ The material you are
spraying should be at
room temperature
➞ Cross spray (Fig. 8)
➞ Closer to the object