15. Adjusting the flow time
15.1 Set the desired temperature of the mixed water.
15.2 Remove the cover platelet.
a: Blade width 3 mm
15.3 Use a screwdriver to set the flow time.
a: Blade width 3 mm
+ longer flow time (max. 50 s)
– shorter flow time (min. 1 s)
15.4 Trigger the fitting to measure the flow time.
15.5 Once the desired flow time has been set, put the cover plate place.
16. Maintenance and care
The fitting must be checked and maintained at regular intervals, depending on the
water quality and in accordance with the local conditions and rules and regulations
applicable at the site.
Maintain the following components:
• Aerator/shower head (see instructions for outlet/shower head)
• Filters (see
• Non-return valve (see
Use suitable cleaning agents which do not attack the fitting in a proper manner and
rinse with water after use. High-pressure cleaners must not be used for cleaning.
Removing the cover plate
For some maintenance tasks, the cover plate must be removed.
16.1 Remove the cover platelet (d).
16.2 Release the screw (c) and the disk.
16.3 Remove the temperature selector (b).
16.4 Remove the rosette (a).
16.5 Remove the lower screws (c) from the cover plate.
16.6 Pull the bottom of the cover plate (b) forwards and detach at the top.
16.7 Close the water volume regulator (see
16.8 Trigger the fitting.
10
Chapter
17.)
Chapter
20.)
Work step
10.2).