10.7 Install the fitting (h) with new seals.
10.8 Open the water volume controls (see
10.9 Check the water connections for leaks.
10.10 Install the frame (i) in a horizontal position.
10.11 Shorten the spacer sleeves (k) to fit the distance from the front edge of the wall unit
to the front edge of the tiles, as required.
Simplified drawing without fitting
10.12 Release the screw (n) with its disk.
10.13 Remove the temperature selector (m) and the stop ring (l).
10.14 Pull the protective foil off the cover plate.
10.15 Seal the cover plate, e.g. with Chromol (not part of the delivery scope, see Acces-
sories
Chapter
10.16 Insert the top of the cover plate (o) into the frame tabs and fit.
10.17 Fasten the cover plate at the bottom, using screws (p).
10.18 Push on the rosette (r).
10.19 Check the flow time and adjust where necessary (see
10.20 Press the cover platelets (s) into position.
10.21 Fit the rosette (t) in such a way that the markings are at the top.
10.22 Turn the adjustment nut (u) so that the two markings (v) are aligned.
☞
The maximum water temperature has been set to 38°C
10.23 If necessary, set the scald protection to another temperature (see
10.24 Mount the stop ring (l) in such a way that the marking (x) is centred below the stop
ring, centrally below the markings (w) for the rosette.
☞
Important!
Mount the temperature selector (m) in such a way that the stop is flush against the
stop ring crosspiece.
10.25 Push the temperature selector (m) onto the stop ring (l).
10.26 Attach the temperature selector (m) and its screw (n) and disk to the fitting.
tightening torque: 1 Nm
10.27 Fit the cover platelet (y).
11. Function
Trigger the flow of water
11.1 Press the pressure cap.
• The water will flow.
• The water flow stops automatically once the preset flow time has expired.
The flow time is adjustable from 1 - 50 seconds.
Temperature selection
22).
Work Step 4.2
).
Chapter
15.).
Chapter
14.).
7