If damaged, further operation of the unit is
not permitted. The unit must be disconnect-
ted from the power supply (switch off the
mains fuse and secure it against being
switched back on again). Have the connec-
tion cable replaced by a trained electrician.
13. Fault rectification
Fault finding and repairs only permissible
when carried out by trained specialists.
Fault
Cause, measure
Fan does
No mains voltage. Check
not switch on.
whether the mains fuse has
failed. Switch on if
necessary.
Motor's thermal
Motor too hot. Leave the
overload
unit switched off until the
protection
motor and the temperature
switches the fan
limiter cool down. Cool-
off.
down time can be up to
30 minutes. Only then,
switch the unit back on.
Impeller is blocked.
Fan does
Check impeller and clean
not switch on.
if necessary.
Impeller not
Switch off unit. Switch off all
turning.
supply circuits – switch off
mains fuse, secure against
being accidentally switched
back on and position a
visible warning sign. Ensure
that the impeller is not
blocked by foreign bodies.
If the fault persists, disconnect unit
from the power supply, fit a sign
prohibiting it from being switched
back on and have cause of error
investigated by a trained electrician.
If faults reoccur, send the unit to our
factory for repairs.
14. Spare parts
Spare parts may only be sourced
from and fitted by a specialist
installer.
Item
Designation
1
Shutter,
complete
2
Connecting
flange, complete
Connecting
flange, complete
2.1
Motor with
screws
2.2
Impeller with
clamping ring
3
Internal
housing,
complete
Internal
housing,
complete
13
Pull-switch,
complete
In case of questions, please contact:
Maico Elektroapparate-Fabrik GmbH
Steinbeisstraße 20
78056 Villingen-Schwenningen, Germany
Tel. +49 7720 694 445 / Fax +49 7720 694 175
E-mail: ersatzteilservice@maico.de
15. Dismantling
Dismantling may only be undertaken by a
trained electrician.
16. Environmentally responsible
disposal
The unit and the packaging contain parts that
can be recycled, and should not end up in the
domestic waste.
Dispose of the packaging material in an
environmentally-friendly way, in compliance
with the regulations valid in the country where
you are.
At the end of its service life, dispose of the
unit in an environmentally-friendly way, in
compliance with the regulations valid in the
country where you are.
12. Maintenance │ UK
Type
Article no.
15
0059.0144.9000
15 P
15
E059.0140.9000
15 P
E059.0140.9100
15
0156.0093.0001
15
0061.0119.0000
15 P
15
0059.0141.9000
15 P
E059.0141.9100
15 P
E157.0794.0000