Warning Lights - Erreka KM 600S Manual De Instrucciones

Accionadores para portas de correr
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

Elements:
A.- Connector for radio receiver.
B.- Aerial connection terminals.
C.- 10-dip selector.
D.- Signal connector.
E.- Operation for pedestrians push-buttons.
F.- Open - Close push-buttons.
Potentiometer:
L.- Garage light (3-90 sec.)
G.- Waiting time (0-90 sec.)
N.- Couple regulation.
H.- End of run reed valve Close.
I.- End of run reed valve Open.
J.- General panel switch.
STARTING
Before feeding the panel to the mains, connect the various peripherals to the panel.
Important: Do not forget to connect the earth cable.
1.- Connect the panel to the mains (general ON-OFF switch).
2.- Check that the opening movement of the door coincides with that of the motor and its correspon
ding end of run.
- Check the turning directions of the motor with the push-buttons (F). If they do not coincide, exchange the cables of terminals
16 and 17 (RL 2 and RL 1).
- Check that the ends of run operate correctly by passing a magnet in front of the valves (H and I) and checking that leds 6
and 7 turn off correctly. (Valve I – Open corresponds to Led DL6 and valve H – Close corresponds to Led DL7).
3.- Regulating the force of the motor.
- Set the couple potentiometer (N) to the minimum by turning it anti-clockwise. With the motor running turn it progressively
clockwise until the motor has sufficient force to move the door all along its run.
4.- Selector operations (G).
DIP 1-ON
Enables the programming.
DIP 2-ON
Learns the total run.
DIP 1-ON
Enables the programming.
DIP 3-ON
Learns the pedestrian run.
DIP 1-ON
Enables programming.
DIP 4-ON
Records total openning code/chanel.
DIP 1-ON
Enables programming.
DIP 6-ON
Records pedestrian openning code/chanel.
DIP 2-ON
Lamp early warning (3 sec.)
DIP 3-ON
Step by step operation.
DIP 3-OFF
Community operation.
DIP 4-ON
Automatic cycle.
DIP 4-OFF
Semi-automatic cycle.

Warning lights:

DL1.- Waiting time.
DL2.- Radio code recording.
DL3.- Manoeuvre recording.
DL4.- Open relay.
DL5.- Close relay.
DL6.- End of run Open.
DL7.- End of run Close.
DL8.- Safety on opening.
DL9.- Safety on closing.
DL10.- Entry pedestrian door.
DL11.- Total aperture entry.
DL12.- Radio signal.
DL13.- Encoder.
DL14.- 220 v power supply.
DIP 5-ON
DIP 5-OFF
DIP 6-ON
DIP 6-OFF
DIP 7-ON
DIP 7-OFF
DIP 8-ON
DIP 8-OFF
DIP9-OFF
DIP10-ON
DIP10-OFF
20
Entry terminals:
1-2.- Start 1. Total opening.
2-3.- Start 2. Opening for pedestrians.
4-5.- Safety on opening.
5-6.- Safety on closing.
7-8.- End of run Open.
8-9.- End of run Close.
10.- Outgoing 24 v.
11-12-13.- Encoder signal.
14.- Garage light (free from voltage).
15.- Bright light (outgoing 220 v.).
16-17-18.- Single-phase motor
(condenser between terminals 16 and 17 ).
19-20.- 220 v power supply.
21.- Earth.
Optional automatic.
NO optional automatic.
Flashing lamp outlet.
Bright light outlet.
Disabled encoder.
Disabled encoder. Eliminating the
encoder involves eliminating the
internal security mechanism of
the motor.
Gentle stop activated.
Gentle stop deactivated.
Turn always to OFF position.
Ramp deceleration.
Instant deceleration.
Both decelerations only work with the
soft stop activated (DIP 8 ON).