The equipment may be used only for the tasks it
is designed to handle. Any other use is deemed
to be a case of misuse. The user/operator and not
the manufacturer will be liable for any damage or
injuries of any kind resulting from such misuse.
Please note that our equipment has not been de-
signed for use in commercial, trade or industrial
applications. Our warranty will be voided if the
equipment is used in commercial, trade or indust-
rial businesses or for equivalent purposes.
Caution!
Residual risks
Even if you use this electric power tool in
accordance with instructions, certain resi-
dual risks cannot be rules out. The following
hazards may arise in connection with the
equipment's construction and layout:
•
Lung damage if no suitable protective dust
mask is used.
•
Damage to hearing if no suitable ear protec-
tion is used.
•
Health damage caused by hand-arm vib-
rations if the equipment is used over a pro-
longed period or is not properly guided and
maintained.
•
Injuries and material damage caused by fly-
ing parts.
•
Cut injuries if suitable protective clothing is
not worn.
Danger!
The electric power tool generates an electro-
magnetic fi eld during operation. Under certain
circumstances this fi eld may actively or passively
impede medical implants. To reduce the risk of
serious or fatal injuries, we recommend persons
with medical implants to consult their doctor and
the manufacturer of the medical implant prior to
using the equipment.
Anl_GC_CT_18_24_Li_Kit_1x_2Ah_SPK9.indb 20
GB
4. Technical data
Speed n
.............................................8,500 min
0
Cutting circle .......................................... Ø 24 cm
Protection class ................................................III
Sound power level L
WA
Sound pressure level L
Sound power level guaranteed L
K uncertainty ...................................... 2.17 dB (A)
Vibration ..................................................5.8 m/s
K uncertainty .......................................... 2.3 m/s²
Sound pressure level
at the operator's ear ............................... 79 dB(A)
K uncertainty ........................................... 3 dB (A)
Power-X-Change lithium-ion rechargeable
battery
Voltage: .................................................. 18 V DC
Capacity: ................................................... 2.0 Ah
Number of cells: ............................................... 5
Important!
The equipment is allowed to be used only with the
lithium-ion rechargeable batteries of the Power-X-
Change series!
Charging unit Power-X-Change 18V
Mains voltage ................... 200-250 V ~ 50-60 Hz
Output
Rated voltage ........................................ 20 V d. c.
Rated current ........................................ 3000 mA
Protection class ............................................. II/
Important!
The charging unit is allowed to be used only for
the lithium-ion batteries of the Power-X-Change
series!
The machine noise might exceed 85 dB (A). The
operator will require noise protection measures
if this is the case. The noise is measured in ac-
cordance with EN ISO 11201:2010 and EN ISO
3744:2010. The value of the vibrations emitted by
the handle was determined in accordance with
EN 28662-1:1992.
Important.
The vibration value changes according to the
area of application of the electric equipment and
may exceed the specifi ed value in exceptional
circumstances.
- 20 -
-1
....................... 88.1 dB (A)
...................... 79 dB (A)
pA
........ 90 dB (A)
WA
2
14.07.2020 14:55:21