Recommended Spare Parts; Troubleshooting - Nilfisk cfm T26 Plus Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Recommended spare parts

The following is a list of spare parts that should be kept ready at hand in order to speed up maintenance operations.
Refer to the manufacturer's spare parts catalogue when ordering spare parts.
Problem
The vacuum cleaner suddenly stops
Dust leaks from the vacuum cleaner
The vacuum cleaner blows instead of
vacuuming
Electrostatic current on the vacuum
cleaner
02/2013
Description
Star filter kit
Primary cartridge filter kit
Filter ring gasket
Filter ring gasket ss
Filter chamber gasket
Filter clamp
Absolute filter

Troubleshooting

Cause
Clogged primary filter
Clogged vacuum hose
Circuit breaker activation
The filter is torn
Inadequate filter
Incorrect connection to the electrical mains
Non existent or inefficient grounding
13
T26 Plus - T48 Plus - T63 Plus
Model
T26 Plus
T48 Plus
40000492
4089100114
Z8 17026
Z8 17126
40000762
Z8 18079
4081700935
Remedy
Shake the filter. Replace it if necessary
Check the vacuum hose and clean it.
Check the setting.
Check the motor electrical input. Contact
an authorised after-sales service centre if
necessary.
Replace it with another of identical type.
Replace it with another of a suitable category
and check.
Ask for assistance from qualified personnel to
perform the correct phase connection.
See page 8, Starting up chapter
Check all ground connections. Especially check
the inlet.
T63 Plus
4089100053
US
C386

Hide quick links:

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

T48 plusT63 plus

Tabla de contenido