Problem
The appliance does not turn
on.
The coffee is not coming out
of the discharge opening
correctly.
The motor gets blocked.
Make sure it is plugged in.
•
Make sure the safety circuit breaker is closed.
•
Check that the main switch of the appliance is ON.
•
If the problem occurs itself after a long period of intensive
•
use or overfilling, the motor could be in thermal protection
lock! Wait at least 20 minutes and try again. The waiting
time can be reduced by putting the appliance in a cool
place.
Check that the coffee discharge opening is free.
•
If the motor gets blocked due to incorrect regulation of
•
grinding or to the presence of a foreign body in the burrs,
try increasing to the coarsest grain size by turning the
grinding adjustment disc clockwise (4 Fig. 1).
If this is not enough, switch off the appliance, disconnect
the plug from the socket and consult technically qualified
personnel.
Solution