Speck BADU Eco Motion Manual De Uso página 29

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 291
The "Info" screen
INFO
FILTER OFF
The safety enable contacts S1 and S2 have to be
switched with the internal auxiliary voltage of 24 V so that
the pump can be started. A jumper is already inserted in
the factory
The display value of the pump's consumption is not a real
measured value, but is rather based on measurements and
calculations of the highest possible power input of the pump.
The display value is only calculated with reference to the motor
speed and not the actual load.
06|2017
In the "Info" screen time-controlled
F.PRO. 1
filtering can be switched on and off by
100
%
using the "F1" button. The filter times
TIME
are set in the menu under "Filter".
TH 14:01
EXTRAS
The operating mode that is currently
WG27.50.052-2-P
active is displayed at the top right of the
display.
When "Filter" is activated, "Filter" or
"F.Pro.x" is displayed with "x" standing
for the programme number which can
vary from 1 to 8. When "Filter" is
displayed, the filter programme is
activated, but no programme is currently
stored.
The "F2" button opens the "Extra" menu.
The speed can be turned up and down
temporarily by using the cursor buttons.
This change is reset when a new action
is taken, for example when a new filter
programme is started.
The display of the time, operating hours,
current consumption, total consumption
and the next backwash is rotated
automatically. However, it can also be
changed manually by using the left and
right cursor buttons.
EN 29

Publicidad

Tabla de contenido
loading

Tabla de contenido