Speck BADU Eco Motion Manual De Uso página 34

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 291
Priming time
PRIMING MODE
PRIMING TIME
SPEED
PERIOD
External controls
EXTERNAL
EXTERNAL
EXTERNAL
EXTERNAL
SIGNAL
RANGE
MIN SPEED
EXTERNAL
SIGNAL
RANGE
MIN SPEED
MAX SPEED
EN 34
The priming time can be switched on
FILTER
and off. It becomes active at every
ON
100 %
pump start, in as far as it is switched on.
3 MIN
If the pump is currently in priming mode,
this is indicated in the operation mode
WG27.50.069-2-P
display by the text "Priming".
The speed is to be set from 50 - 100 %
and the time from 1 - 10 minutes.
In addition to ist own programmes, the
FILTER
pump can also be controlled by an
OFF
external control unit.
Three setting options are available to
this purpose: "Off", "Analogue" and
WG27.50.070-2-P
"Fixed speed digital".
The signal types "Current" and "Voltage"
ANALOGUE
are available with the analogue control.
ANALOGUE
CURRENT
0-20mA
The signal range with a current control
35 %
is 0 - 20 mA or 4 - 20 mA.
WG27.50.071-2-P
The signal range with a voltage control
ANALOGUE
is 0 - 10 V or 2 - 10 V.
CURRENT
0-20mA
A minimum and a maximum speed can
35 %
100 %
be assigned in accordance with the
signal range.
WG27.50.072-2-P
If the analogue control is activated, this
is indicated in the operating mode
display by the text "Analogue".
06|2017

Publicidad

Tabla de contenido
loading

Tabla de contenido