4-wire
connection:
Direct Wire
IMPORTANT:
A 4-wire
connection
is required
for mobile
homes and where local codes do
not permit
the use of 3-wire
connections.
Direct
wire cable must have 5 ft (1.52 m) of extra length so dryer can be moved
if needed.
Strip 5" (12.7 cm) of outer covering
from end of cable,
leaving bare ground
wire at 5"
(12.7 cm). Cut 11/2" (3.8 cm) from 3 remaining
wires.
Strip insulation
back 1" (2.5 cm). Shape
ends of wires
into a hook shape.
(12, 7
When
connecting
to the terminal
block,
place the hooked end of the wire under the screw of
the terminal
block (hook facing
right), squeeze
hooked
end together
and tighten
screw, as
shown.
1.
Remove center
silver-colored
terminal
block
screw.
Remove
neutral ground
wire from external
ground
conductor
screw. Connect
neutral
ground
wire and place the hooked
end (hook facing
right) of the neutral
wire (white or
center wire) of direct
wire cable under the center screw of the terminal
block.
Squeeze
hooked
ends together.
Tighten
screw.
......... C
A. [xterna/
ground
conductor
screw
- Dotted
line shows
position
of NEU FRAL ground
wire before
being
moved
to
center
silv_'r-color_'d
terminal
block
screw.
B. C_'nter silver-color_'d
terminal
block
scr_'\,v
C. Neutral
wire
(white
or center
wir_')
D. _/4" ( h 9 cm) UL listed strain
reli_'f
E. Neutral
ground
wire