• Example: when using in 25-channel mode, you will have to set the start address of the first
unit to 001 (CH1~25), the second unit to 026 (1 + 25) (CH26~51), the third to 051 (26 + 25)
(CH52~77), and so on.
7.1
4 channel mode (4CH): basic mode
Notes:
• When a signal is present on CH3, CH2 is ignored (overridden). Only when no signal is
present on CH3 will the value on CH2 display the corresponding static macro.
• Dynamic macros and set speed are explained in detail in §7.5 resp §7.6.
7.2
9 channel mode (9CH): zone mode
• In 9 channel mode, the blinder is divided in to 5 zones that can be dimmed individually. Each
zone is vertical row of lamps (see image).
Notes:
• When a signal is present on CH3, CH2 is ignored (overridden). Only when no signal is
present on CH3 will the value on CH2 display the corresponding static macro.
• Dynamic macros and set speed are explained in detail in §7.5 resp §7.6.
7.3
25 channel mode (25CH): matrix mode
• In 25 channel mode, the dim level of each lamp can be controlled individually (see table below).
CH1
lamp 1 dimmer 0 ~ 100%
CH2
lamp 2 dimmer 0 ~ 100%
CH3
lamp 3 dimmer 0 ~ 100%
CH4
lamp 4 dimmer 0 ~ 100%
CH5
lamp 5 dimmer 0 ~ 100%
CH6
lamp 6 dimmer 0 ~ 100%
CH7
lamp 7 dimmer 0 ~ 100%
CH8
lamp 8 dimmer 0 ~ 100%
CH9
lamp 9 dimmer 0 ~ 100%
CH10
lamp 10 dimmer 0 ~ 100%
CH11
lamp 11 dimmer 0 ~ 100%
CH12
lamp 12 dimmer 0 ~ 100%
CH13
lamp 13 dimmer 0 ~ 100%
Notes:
• When a signal is present on CH3, CH2 and CH5~CH25 are ignored (overridden).
• When a signal is present on CH2 and no signal is placed on CH3, CH5~CH25 are ignored
(overridden).
• Only when there are no signals on CH2 or CH3 will the signals on CH5~CH29 become valid
and the corresponding lamp will be dimmed.
12/05/2010
VDP7525BL
CH1
General dimmer 0 ~ 100%
CH2
static macros
CH3
dynamic macros
CH4
set speed for CH3
CH1
CH2
CH3
CH4
CH5
CH6
CH7
CH8
CH9
General dimmer 0 ~ 100%
static macros
dynamic macros
set speed for CH3
zone 1 dimmer 0 ~ 100%
zone 2 dimmer 0 ~ 100%
zone 3 dimmer 0 ~ 100%
zone 4 dimmer 0 ~ 100%
zone 5 dimmer 0 ~ 100%
CH14
lamp 14 dimmer 0 ~ 100%
CH15
lamp 15 dimmer 0 ~ 100%
CH16
lamp 16 dimmer 0 ~ 100%
CH17
lamp 17 dimmer 0 ~ 100%
CH18
lamp 18 dimmer 0 ~ 100%
CH19
lamp 19 dimmer 0 ~ 100%
CH20
lamp 20 dimmer 0 ~ 100%
CH21
lamp 21 dimmer 0 ~ 100%
CH22
lamp 22 dimmer 0 ~ 100%
CH23
lamp 23 dimmer 0 ~ 100%
CH24
lamp 24 dimmer 0 ~ 100%
CH25
lamp 25 dimmer 0 ~ 100%