Maintenance
The digital manifold requires maintenance work when used regularly:
Clean the screen and the housing surface with a cloth and
•
cleaning agent.
Do not use corrosive cleaning agents or solvents to clean the
•
unit. Weak household cleaners and soap suds may be used.
The connectors and filling hoses must be visually inspected for
•
mechanical damage before each use and replaced if damaged.
The seals of a manifold are naturally subject to mechanical and
•
ageing-related wear and tear. The manifold must therefore be
checked regularly by the user for leaks.
If any valves are leaking, the piston must be replaced (M4-6-04-
•
R/10).
The REFCO special tool M4-6-11-T must be used to change the
•
sight glass on the manifold.
7.1
Refrigerant update
Log in to the App
Under refrigerants you will find the latest refrigerant versions.
Select the latest refrigerants and email them to yourself.
Connect the REFMATE to your PC via USB cable.
When the REFMATE is turned on, a new drive
appears in the explorer.
Bedienungsanleitung REFMATE
and go to the device update section.
20