Spare Parts Service; Warranty Conditions; Replacing The Filter - Schneider Airsystems FEH-FDM/FF/AF 1/2 Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

GB
FEH/AF
1. Close the stop cock upstream of the filter
unit.
2. Set the working pressure to 0 bar.
3. Press the quick-vent valve (Fig. 1a, pos.
06) until air no longer escapes.
10.2
Maintaining/Cleaning the
filter pressure reducer
1. Remove the vessel from the filter pres-
sure reducer, collect condensate.
2. Unscrew the filter insert (Fig. 4a, pos.
11) and clean in soapy water (max. 50
°C).
3. Unscrew the filter support (Fig. 5a, pos.
16). Remove the valve (Fig. 5a, pos. 14)
and spring (Fig. 5a, pos. 15).
4. Clean the valve and lubricate with
grease.
5. Installation is in reverse order.
12
Troubleshooting
Observe the safety instructions!
Problem
A
Water
in
the
pressed air
B
Dirt particles in the
compressed air
C
Oil in the compressed
air
If necessary, contact our service staff, see last page.
13

Spare parts service

Visit
our
website
tems.com/td/ for the latest version of all ex-
ploded drawings and spare parts lists for our
products. If you have any special questions,
please consult the Schneider Airsystems Ser-
vice centre in your country (addresses in the
service appendix) or your local dealer.
14

Warranty conditions

Basis for warranty claims: complete unit
in original condition/proof of purchase.
According to legal provisions, you re-
ceive the following warranty against
material and manufacturing defects:
8
Cause
com-
No upstream compressed air cold
dryer
Filter elements worn
Filter elements worn
Activated
charcoal
installed
www.schneider-airsys-
10.3

Replacing the filter

Always wear gloves when replacing the filter.
Suitable spare filters: see spare parts list.
1. Unscrew the filter container.
2. Unscrew the old filter element. (Fig. 4a)
Pos. 11 = Filter element (FDM)
Pos. 12 = Microfilter
Pos. 13 = Activated charcoal filter
3. Installation is in reverse order.
11
Decommissioning
Storage: Clean, dry, free from dust, above
5° C.
Disposal: Dispose of packaging / machine
according to valid statutory regulations.
Remedy
X
Install an upstream com-
pressed air cold dryer
X
Replace filter elements
X
Replace filter elements
filter
not
Install activated charcoal filter
private use only: 2 years,
commercial use: 1 year.
Excluded from warranty claims: Wear or
expendable parts, improper use, improper
installation, overloading / incorrect pressure,
manipulation / inappropriate use, inade-
quate / incorrect / lack of maintenance or lu-
brication, bumps / impacts, dust / dirt
accumulation, unauthorised / incorrect work-
ing procedures, impure / insufficiently fil-
tered compressed air, failure to read the
instruction manual, incorrect operating re-
sources / materials.

Publicidad

Capítulos

Tabla de contenido
loading

Este manual también es adecuado para:

D 424 030Feh-fdm/ff 1/2D 426 030Af 1/2D 640 760

Tabla de contenido