Name and address of relevant, named
location:
TÜV Rheinland LGA Products GmbH
Tillystraße 2
D-90431 Nürnberg
Compilation and storage of technical
documentation:
Sven Zimmermann
STIHL Tirol GmbH
The year of manufacture and machine
number appear on the rating plate of the
machine.
Measured sound power level:
100.8 dB(A)
Guaranteed sound power level:
104 dB(A)
Langkampfen,
2019-01-02 (YYYY-MM-DD)
STIHL Tirol GmbH
p.p.
Head of Design
17. Technical specifications
GHE 105.0
Power
2200 W
0478 201 9915 A - EN
GHE 105.0
Amperage rating
9.8 A
Rated voltage
230 V
Frequency
50 Hz
Speed
2800 rpm
Fuses
16 A*
Protection class
I
Type of protection
Splash proof
(IPX4)
Operating conditions
P40
40 s load time
60 s idle time
Tightening torque
25 Nm
Bolt
Blade disc
Tightening torque
10 Nm
Bolt
Reversible blade
L/W/H
77/48/97 cm
Weight
19 kg
19 kg (CH)
20 kg (GB)
Sound emissions:
In accordance with Directive 2000/14/EC:
Guaranteed sound
power level L
104 dB(A)
WAd
In accordance with Directive 2006/42/EC:
Sound pressure level
at workplace L
93 dB(A)
pA
Uncertainty K
3 dB(A)
pA
* Caution!
In the case of mains fuses of less than
16 A, these may be tripped during start-
up or in the case of high load operation
of the machine.
17.1 REACH
REACH is an EC Directive for the
registration, evaluation, authorisation and
restriction of chemicals.
Information on compliance with the
REACH Directive (EC) No. 1907/2006 is
available from www.stihl.com/reach.
18. Troubleshooting
If necessary, contact a specialist
dealer; STIHL recommends STIHL
specialist dealers.
Fault:
Motor does not start
Possible cause:
– Motor overload protection activated
– No mains voltage
– Electric cable, plug, plug connector or
switch defective
– Fuse in UK plug damaged (only applies
to machines for UK)
– Feed chute not properly closed - safety
cut-off switch actuated (safety interlock)
– Blade disc blocked
– Locking device is not reset
Remedy:
– Allow machine to cool down (
– Check power cable and fuse
(
10.1)
– Check cable, plug, connector and
switch and replace if necessary (by
electrician)
(
10.1)
– Replace fuse
– Close feed chute properly and tighten
screws (
11.3)
8.6)
39