Motor protection filter (inlet filter)
The inlet filter is located in the dust container space. The filter
sits vertically in the rear part of the dust housing. Do not remove
the rubber seal! Pull the filter (black foam) out to the front.
Clean the motor protection after every approx. 10th emptying of
the dust container.
When required, you can clean
the filter with warm water
without any additions. Reinsert
it only after it is completely dry.
WARNING:
• Before cleaning remove the mains lead from the socket.
• Under no circumstances should you immerse the device in water
for cleaning purposes. Otherwise this might result in an electric
shock or fire.
CAUTION:
•
Do not use a wire brush or any abrasive items.
•
Do not use any acidic or abrasive detergents.
Clean the housing with a soft, dry cloth without additives.
Storage
•
Let the device cool down completely.
•
Wind the cable completely.
•
Please insert the hook of the floor nozzle into the parking
assistant on the rear of the device.
•
When you place the appliance vertically: Hang the hook of
the accessory holder (on the suction tube) into the parking
aid on the underside of the appliance.
Troubleshooting
•
The Device Does Not Work.
Remedy:
Check the connection to the mains.
Check the position of the switch.
Outlet filter (7)
The appliance is also equipped with an outlet filter. It is located
on the rear of the device under the parking aid.
We recommend that you clean the filter every 6 months to
assure correct functioning.
1. Push the lever to the left
and remove the ventilation
grid.
2. Remove the filter insert
and clean it as described
above.
3. Place the completely dry filter back into the ventilation grille.
4. Put the ventilation grille back on the appliance. Observe the
guide lugs. The ventilation grid must engage audibly.
Cleaning
•
The device does not suck up anything.
Possible Cause:
The dust collector is full.
Remedy:
Empty the dust collector.
or
Possible Cause:
The filters are dirty.
Remedy:
Clean the components.
or
Possible Cause:
There is a foreign body in the suction tube or the nozzle.
Remedy:
Check the accessories for foreign bodies.
Model:.......................................................................BS 1294 N
Power supply:....................................... 220 - 240 V~, 50 / 60 Hz
Protection class: ......................................................................
Net weight: ........................................................approx. 4.70 kg
The right to make technical and design modifications in the
course of continuous product development remains reserved.
Technical Data