Regarding noise
• In installing work, choose a place that can fully bear the weight of the air condi-
tioner, and where noise and vibration can be reduced.
• Choose a place where cool or warm air and noise from the outdoor air outlet of the
air conditioner does not inconvenience the neighbors.
• If any alien object is placed near the outdoor air outlet of the air conditioner,
decreased performance and increased noise can result. Avoid placing any obsta-
cles adjacent to the air outlet.
• If the air conditioner produces any abnormal sound, consult with your dealer.
8. Specifications
PEFY-WP•VMA-E series
Item
Power source
Cooling capacity
/ Heating capacity
*1
Dimension
Height / Width / Depth
Net weight
Airflow rate (Low-Middle-High)
Fan
External static pressure
*2
Sound level (Low-Middle-High)
*3
Filter
PFFY-WP•VLRMM-E series
Item
Power source
Cooling capacity
/ Heating capacity
*1
Dimension
Height / Width / Depth
Net weight
Airflow rate (Low-Middle-High)
Fan
External static pressure
*4
Sound level (Low-Middle-High)
*3
Filter
Notes: *
Operation temperature of indoor unit.
Cooling mode: 15 °C WB - 24 °C WB
Heating mode: 15 °C DB - 27 °C DB
*1 Cooling/Heating capacity indicates the maximum value at operation under the following condition.
Cooling: Indoor: 27 °C DB/19 °C WB
Heating: Indoor: 20 °C DB
*2 The external static pressure is set to 50 Pa at factory shipment.
*3 The operating noise is the data that was obtained in an anechoic room.
*4 The external static pressure is set to 20 Pa at factory shipment.
Model
WP20VMA-E
kW
2.2/2.5
*1
mm
250/700/732
kg
21
m
/min
7.5-9.0-10.5
3
Pa
35/50/70/100/150
dB(A)
23-26-29
Model
WP20VLRMM-E
kW
2.2/2.5
*1
mm
639/886/220
kg
22
m
/min
4.5-5.0-6.0
3
Pa
20/40/60
dB(A)
31-33-38
Outdoor: 35 °C DB
Outdoor: 7 °C DB/6 °C WB
Maintenance and inspection
• If the air conditioner is used throughout several seasons, the insides can get dirty,
reducing the performance.
Depending upon the conditions of usage, foul odors can be generated and drain-
age can deteriorate due to dust and dirt, etc.
WP25VMA-E
WP32VMA-E
~220-240V 50/60Hz
2.8/3.2
3.6/4.0
250/900/732
250/900/732
26
26
10.0-12.0-14.0
12.0-14.5-17.0
35/50/70/100/150
35/50/70/100/150
23-27-30
25-29-32
Standard filter
WP25VLRMM-E
WP32VLRMM-E
~220-240V 50/60Hz
2.8/3.2
3.6/4.0
639/1006/220
639/1006/220
25
25
6.0-7.0-8.0
7.5-9.0-10.5
20/40/60
20/40/60
31-33-38
31-35-38
Standard filter
WP40VMA-E
WP50VMA-E
4.5/5.0
5.6/6.3
250/1100/732
250/1100/732
31
31
14.5-18.0-21.0
14.5-18.0-21.0
35/50/70/100/150
35/50/70/100/150
26-29-34
26-29-34
WP40VLRMM-E
WP50VLRMM-E
4.5/5.0
5.6/6.3
639/1246/220
639/1246/220
29
29
8.0-10.0-11.5
10.5-13.0-15.0
20/40/60
20/40/60
34-37-40
37-42-45
7