Troubleshooting
Problem
MixRite does not
operate
MixRite does not
draw
The MixRite
makes scratching
noises
Correct installation will prevent damages and malfunctions of the
It is strongly recommended to install a back flow preventor before the injector
on the main water line.
A vacuum release unit should be installed at the outlet of the MixRite in order
to prevent undesired suction of additive when the water line is draining.
A master valve must be installed before the injector, to be opened
only for the operation of the injector to prevent water hammer
damage to the injector.
Check
Check that the intake and outlet
valves are open
Check that the water filter isn't
clogged
Check that water is flowing in the
line
Check that springs are not broken
Open pump lid & remove piston
Check that cylinder is not
scratched
Check that piston seals are not
damaged
Dismantle the suction pump and
check the suction seal for damage
Check if there is liquid in the
additive container
Check if suction pipe is immersed
and not folded
Check suction filter to see if it is
blocked and if it is immersed in the
additive tank
MixRite
9
Solution
Open the valve
Clean the filter
Open main and
outlet valve
Change the broken
spring
Change cylinder
Change the seals
Change the suction
seal
Add liquid to the
container
Straighten or
change the pipe
Clean and rinse
suction filter, Fill
liquid into tank to
cover filter