6.1 REPLACING THE BATTERIES
The remaining battery charge level is indicated by the
When the battery is flat (the
automatically switches to standby. When the battery is low, display of the "BAtt" message indicates that the
measurement requested requires too much energy and cannot be made.
Note: when rechargeable batteries are used, this fact must be entered in the configuration of the instrument
("SET-UP" mode) to prevent incorrect operation of the instrument (risk of erroneous measurements
or malfunction of the instrument).
Check that none of the input terminals are connected and that the switch is
When the batteries are removed, there is enough reserve energy to preserve the date and time for one minute. If this
time is exceeded, the instrument, when next started up, prompts the user to check the date and time by displaying
the flashing message "tIME" for 2 seconds before displaying new measurements.
6.2 STORAGE
If the instrument is to be stored for more than 2 months, remove the batteries. It will then be necessary to reset the
instrument's time when it is next used.
6.3 CLEANING
Clean the housing of the instrument regularly. This can be done with a damp cloth or soapy water. Do not use
alcohol, solvents, or hydrocarbons.
6.4 METROLOGICAL VERIFICATION
Like all measuring and testing devices, the instrument requires periodic verification.
We recommend checking the instrument at least once a year. For verifications and calibrations, contact our
COFRAC-accredited metrology laboratories or the MANUMESURE agencies.
Information and coordinates on request: Tel.: 02 31 64 51 43
6.5 WARRANTY
Unless otherwise stated, our warranty is valid for 12 months following the date on which the equipment is made
available (extract from our General Conditions of Sale, available on request)).
6.6 CUSTOMER SERVICE
For maintenance work, use only specified spare parts.
The manufacturer cannot be held liable for any accident that occurs following a repair done other
than by its Customer Service Department or an approved repairer.
Repair under and out of warranty:
Send the instrument to one of the MANUMESURE regional agencies, approved by Chauvin Arnoux
Information and coordinates on request:
Repair outside mainland France:
For any repair (under or out of warranty), send the instrument back to the dealer.
6 MAINTENANCE
symbol flashes), the instrument emits an audible stop signal (5 beeps), then
set to OFF before opening the instrument.
Tel.: 02 31 64 51 43 - Fax: 02 31 64 51 09
symbol.
-
Fax: 02 31 64 51 09
72